About Output Device Programming (*79/*80 Menu Mode)
Advertising
Output Devices:
The VISTA-20P system supports up to 16 relays and/or Powerline Carrier devices
(X-10 devices) plus 2 built-in trigger outputs in any combination. These 18 “outputs” are assigned to system-wide output numbers (01-18). Use *79 Menu Mode to assign output numbers and map them to device addresses.
About Output Device Programming (.79/.80 Menu Mode) Output Devices: The VISTA-20P system supports up to 16 relays and/or Powerline Carrier devices (X-10 devices) plus 2 built-in trigger outputs in any combination. These 18 “outputs” are assigned to system-wide output numbers (01. Honeywell Vista 15P/20P Customer User Guide Security Alarm Corporation Page 2 To ARM the system and go AWAY 1. Secure all doors and windows. Enter your 4-digit USER code and press 2. Red ARMED message will display. To ARM the system and STAY in building 1. Secure all doors and windows.
![]()
The VISTA-15P supports 8 relays and 2 built-in trigger outputs (total 10 outputs).
Output Functions: The system also provides installer-defined output functions, which can be assigned to
any of the physical outputs. Therefore, the action of any one of the outputs can be
based on as many of these functions as desired. This lets a single relay or X-10 device perform many functions.
The controls support up to 48 output functions.
Download bootable system32 drivers pci.sys. Use *80 Menu Mode to define output functions.
Relays and output devices are not recommended for life safety applications. Traktor pro mac download.
NOTE: When navigating the *79 and *80 menus: The [
✱
] key is used to accept an entry and advance to
the next prompt. The [#] key is used to revert back to the last question to check or change an entry. Press
[
✱
] to go forward again.
Programming Output Devices
![]()
1. Use *79 Menu Mode to assign module and output numbers and map them to device addresses.
NOTE: You must map output devices using *79 Menu Mode before you can use *80 menu Mode.
2. Use *80 Menu Mode to create output definitions, which control the output devices, if desired.
3. Use *81 Zone List Menu mode to define zone lists for use with output devices if the device action is
based on more than one zone.
• To program a device for manual activation (user code + [#] [7] / [#] [8] + 2-digit device number) or for
scheduled automatic activation, simply map the device using *79 Menu mode.
• To program a device to automatically activate upon a system event (or function key), use *79 Menu mode to
map the device, then use *80 Menu mode to define the automated device action.
*79 Menu Mode: Output Device Mapping
Use this menu to assign Relay Module device addresses and specific relay numbers, and Powerline Carrier
unit numbers. The system is based on predefined module addresses for 4204 and 4229 modules. Refer to the table shown at the “Module Address” prompt on the next page and set the modules’ addresses (via module DIP switches) accordingly.
The following table shows how these outputs are identified.
Output Identification
This output…
is identified by…
Relays
the Relay Module’s device address and the relay position on that module (i.e. the physical relay
number, 1-4, on that module).
X-10 Device
a house ID (entered in data field *27) and the unit number of the device.
Built-in Outputs
Vista 20p 01 Output Action User Manual Online
the output number assigned, 17 for Trigger 1 and/or 18 for Trigger 2.
Spotify web player download android. Installation and Setup Guide
5-8
Advertising
Vista 20p Panel Manual
This manual is related to the following products:
Popular Brands
Vista 20p 01 Output Action User Manual 2016
Popular manuals
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |