Menu
Amana Over-the-Range Microwave lets Our 1.6 cu. Amana Over-the-Range Microwave lets you easily heat up frozen favorites with the push of a button. Use Auto Defrost to thaw frozen meat for tonight's dinner then use Reheat tomorrow when you're craving some leftovers. GE - General Electric GE 1.6 Cu. Over-the-Range Microwave Oven JVM1653BD004 - User Manuals - User Guide. 1000 Watts JVM1653 2Helpful Information 33 Microwave Terms 33 Care and Cleaning 34 If Something Goes Wrong 39 Before You Call For Service 39 GE Service Numbers 42 Warranty Back Cover GE Appliances Models.
- Ge 1.6 Cu Ft Microwave User Manual Me18h704sfs
- Ge 1.6 Cu Ft Microwave User Manual Online
- 1.6 Cu Ft Countertop Microwave
- Microwave 1.6 Cu Ft
Advertising
- Ge JES1656SJ - 1.6 cu. Full-Size Microwave Pdf User Manuals. View online or download Ge JES1656SJ - 1.6 cu. Full-Size Microwave Owner's Manual.
- Ge JVM1650CH - 1.6 cu. Spacemaker Microwave Oven Pdf User Manuals. View online or download Ge JVM1650CH - 1.6 cu. Spacemaker Microwave Oven Owner's Manual.
For answers to your Monogram
or GE
®
appliance
questions, visit our website at geappliances.com
or call GE Answer Center
®
Amplitube for mac free download. service, 800.626.2000.
340168
Specification Revised 7/13
Listed by
Underwriters
JVM3160DF
GE
®
1.6 cu. ft. Over-the-Range Microwave Oven
Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the
following carefully.
Exhaust Connection: The hood exhaust has been designed to mate with a standard
3-1/4' x 10' rectangular duct. If a round duct is required, a rectangular-to-round transition
adaptor must be used. Do not use less than a 6' diameter duct
Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to
align exhaust with space between studs, or wall should be prepared at the time it is
constructed by leaving enough space between the wall studs to accommodate exhaust.
Maximum Duct Length: For satisfactory air movement, the total duct length of
3-1/4' x 10' rectangular or 6' diameter round duct should not exceed 120 equivalent feet.
Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow
and are equivalent to a section of straight duct which is longer than their actual physical
size. When calculating the total duct length, add the equivalent length of all transitions
and adaptors plus the lengths of all straight duct sections. The chart below shows the
approximate feet of equivalent length of some typical ducts.
following carefully.
Exhaust Connection: The hood exhaust has been designed to mate with a standard
3-1/4' x 10' rectangular duct. If a round duct is required, a rectangular-to-round transition
adaptor must be used. Do not use less than a 6' diameter duct
Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to
align exhaust with space between studs, or wall should be prepared at the time it is
constructed by leaving enough space between the wall studs to accommodate exhaust.
Maximum Duct Length: For satisfactory air movement, the total duct length of
3-1/4' x 10' rectangular or 6' diameter round duct should not exceed 120 equivalent feet.
Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow
and are equivalent to a section of straight duct which is longer than their actual physical
size. When calculating the total duct length, add the equivalent length of all transitions
and adaptors plus the lengths of all straight duct sections. The chart below shows the
approximate feet of equivalent length of some typical ducts.
Duct
Equivalent Feet
A. Rectangular-To-round
Transition Adaptor
5 ft.
B. Wall Cap
40 ft.
C. 90° Elbow Ufc undisputed 3 pc serial key.
10 ft.
D. 45° Elbow
E. 90° Elbow
25 ft.
F. 45° Elbow
5 ft.
G. Roof Cap
24 ft.
Optional Accessories (Available at additional cost)
Filler Panel Kits JX40 and JX46
When replacing a 36' range hood,
When replacing a 36' range hood,
this kit fills in the additional width to
provide a custom built-in
appearance. For installation
between cabinets only; not
for end-of-cabinet installation.
Each kit contains two 3'-wide
filler panels.
Filter Kit JX81L–
Recirculating Charcoal
Filter Kit To be used
Ge 1.6 Cu Ft Microwave User Manual Me18h704sfs
when the Spacemaker
Ge 1.6 Cu Ft Microwave User Manual Online
microwave oven
cannot be vented to
the outside.
Dimensions and Installation Information (in inches)
Advertising
This manual is related to the following products:
1.6 Cu Ft Countertop Microwave
Popular Brands
Microwave 1.6 Cu Ft
Popular manuals